SIL interface module, TeSys island, 24VDC, Isolated switching input for safe stop

Product ID: 9672562 ! Pre Order
Schneider Electric SIL interface module, TeSys island, 24VDC, Isolated switching input for safe stop TPRSM001 | Elektrika.lv

Price and quantity

* Price is valid while product is in stock. if a chosen item is out of stock at the moment, our specialists will inform you about delivery terms and prices.
(0)
  • e-store price

    149.82 / pcs

  • Quantity

  • Total price VAT included (21%)

    149.82

Availability

* The availability of a product in Elektrika warehouses is indicated below. If the product is in the supplier's warehouse, it may take up to 2-12 business days to arrive at Elektrika warehouse.
  • Riga (Marupe)

    0

  • Daugavpils

    0

  • Valmiera

    0

  • Ventspils

    0

Product details

* The displayed pictures may not match the product
  • Manufacturer

    Schneider Electric

  • Manufacturers ID

    TPRSM001

  • EAN

    3606489832872

  • Sustainable by Design
    Green Premium™
    Ilgtspējīgs iepakojums Sustainable Packaging
    Product primary packaging free from single-use plastic and uses recycled cardboard.
    Pārredzamība Transparency
    Assessment of the product environmental impacts along its life-cycle and availability of the data through a Product Environmental Profile.
    RoHS/REACh RoHS/REACh
    Compliant with RoHS/REACh regulations

Product parameters

  • Net Weight

    0.272 kg

  • Sustainability

    +

Additional parameters

+
  • Appendant operation agent (Ex ia)

    -

  • Appendant operation agent (Ex ib)

    -

  • Certified for UL hazardous location class I

    -

  • Certified for UL hazardous location class II

    -

  • Certified for UL hazardous location class III

    -

  • Certified for UL hazardous location division 1

    -

  • Certified for UL hazardous location division 2

    -

  • Certified for UL hazardous location group A (acetylene)

    -

  • Certified for UL hazardous location group B (hydrogen)

    -

  • Certified for UL hazardous location group C (ethylene)

    -

  • Certified for UL hazardous location group D (propane)

    -

  • Certified for UL hazardous location group E (metal dusts)

    -

  • Certified for UL hazardous location group F (carbonaceous dusts)

    -

  • Certified for UL hazardous location group G (non-conductive dusts)

    -

  • Contactor control function block

    +

  • Degree of protection (IP)

    IP20

  • Depth

    114 mm

  • Explosion safety category for dust

    None

  • Explosion safety category for gas

    None

  • Fieldbus connection over separate bus coupler possible

    +

  • Flux controller possible

    -

  • Frequency measurement

    -

  • Front build in possible

    -

  • Function block 2-hand switching

    -

  • Function block access control

    -

  • Function block affirm pushbutton

    -

  • Function block automatic reset

    -

  • Function block contactless working protection installation

    -

  • Function block emergency stop

    -

  • Function block operating mode selection

    -

  • Function block restart blockage

    -

  • Function electronic positioning available

    -

  • Height

    118 mm

  • IO link master

    -

  • Number of HW-interfaces RS-232

    0

  • Number of HW-interfaces RS-422

    0

  • Number of HW-interfaces RS-485

    0

  • Number of HW-interfaces USB

    0

  • Number of HW-interfaces Wireless

    0

  • Number of HW-interfaces industrial Ethernet

    0

  • Number of HW-interfaces other

    2

  • Number of HW-interfaces parallel

    0

  • Number of HW-interfaces serial TTY

    0

  • Number of functions

    1

  • Number of interfaces PROFINET

    0

  • Performance level acc. EN ISO 13849-1

    Level d

  • Rack-assembly possible

    -

  • Radio standard Bluetooth

    -

  • Radio standard GPRS

    -

  • Radio standard GSM

    -

  • Radio standard UMTS

    -

  • Radio standard WLAN 802.11

    -

  • Rail mounting possible

    +

  • SIL according to IEC 61508

    2

  • Single-axis controller possible

    -

  • Single-axis positioning possible

    -

  • Suitable for CNC

    -

  • Suitable for NC

    -

  • Suitable for SSI

    -

  • Suitable for cam controller

    -

  • Suitable for counting

    -

  • Suitable for detection absolute value

    -

  • Suitable for flux measurement

    -

  • Suitable for flying saw

    -

  • Suitable for incremental data detection

    -

  • Suitable for multi-axis control

    -

  • Suitable for multi-axis positioning

    -

  • Suitable for path controller

    -

  • Suitable for pressure control

    -

  • Suitable for safety functions

    +

  • Suitable for temperature control

    -

  • Suitable for weighting

    -

  • Suitable for welding control

    -

  • Supply voltage DC

    20.4 .. 28.8 V

  • Supporting protocol for AS-Interface Safety at Work

    -

  • Supporting protocol for ASI

    -

  • Supporting protocol for CAN

    -

  • Supporting protocol for Data-Highway

    -

  • Supporting protocol for DeviceNet

    -

  • Supporting protocol for DeviceNet Safety

    -

  • Supporting protocol for EtherCAT

    -

  • Supporting protocol for EtherNet/IP

    -

  • Supporting protocol for Foundation Fieldbus

    -

  • Supporting protocol for INTERBUS

    -

  • Supporting protocol for INTERBUS-Safety

    -

  • Supporting protocol for KNX

    -

  • Supporting protocol for LON

    -

  • Supporting protocol for MODBUS

    -

  • Supporting protocol for PROFIBUS

    -

  • Supporting protocol for PROFINET CBA

    -

  • Supporting protocol for PROFINET IO

    -

  • Supporting protocol for PROFIsafe

    -

  • Supporting protocol for SERCOS

    -

  • Supporting protocol for SUCONET

    -

  • Supporting protocol for SafetyBUS p

    -

  • Supporting protocol for TCP/IP

    -

  • Supporting protocol for other bus systems

    +

  • System accessory

    +

  • Voltage type of supply voltage

    DC

  • Wall mounting/direct mounting

    -

  • Width

    25 mm

  • With optical interface

    -

Description

TeSys island SIL interface module, 2 inputs, 1 output. Connected to a TPRBC bus coupler, it allows integration into safety related systems conforming to ISO 13849-1. It is used in connection to one or several SIL motor starter TPRSS. Two isolated switching inputs with common point, 0-24V DC. One relay type output, 1NO, instantaneous opening, potential free. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

  • Monitoring of the mains voltage powering the island
  • Reporting of the voltage to the bus coupler to enable power & energy monitoring
  • Manages motors and other electrical loads up to 80 A (AC-3) / 37 kW/40 hp
  • All adjustments and setting are digitized, no mechanical dials or dip switches
  • Embedded Cybersecurity (Achilles Level 2)


Video

Reviews (0)

+ ADD REVIEW
×
EN