ACT20P-UI-2RCO-AC-S

Product ID: 9649562 In Vendor Inventory
Weidmuller ACT20P-UI-2RCO-AC-S 1238910000 | Elektrika.lv
Weidmuller ACT20P-UI-2RCO-AC-S 1238910000 | Elektrika.lv

Price and quantity

* Price is valid while product is in stock. if a chosen item is out of stock at the moment, our specialists will inform you about delivery terms and prices.
(0)
  • e-store price

    439.31 / pcs.

  • Quantity

  • Total price VAT included (21%)

    439.31

Availability

* The availability of a product in Elektrika warehouses is indicated below. If the product is in the supplier's warehouse, it may take up to 2-12 business days to arrive at Elektrika warehouse.
  • Riga (Marupe)

    0

  • Daugavpils

    0

  • Valmiera

    0

  • Ventspils

    0

  • Vendor stock

    5

Product details

* The displayed pictures may not match the product
  • Manufacturer

    Weidmuller

  • Manufacturers ID

    1238910000

  • EAN

    4050118027075

Product parameters

Additional parameters

+
  • Construction type of device

    Field device

  • Degree of protection (IP)

    IP20

  • Degree of protection (NEMA)

    1

  • Depth

    113.6 mm

  • Galvanic separation between input and output

    +

  • Height

    119.2 mm

  • Inherently safe according to EN 60947-5-6 NAMUR

    -

  • Number of input ranges +5 V ... -5 V

    1

  • Number of input ranges +10 V ... -10 V

    1

  • Number of input ranges -1 V ... +1 V

    1

  • Number of input ranges -2 V ... +2 V

    1

  • Number of input ranges -2.5 V ... +2.5 V

    1

  • Number of input ranges -5 V ... +5 V

    1

  • Number of input ranges -5 mA ... +5 mA

    1

  • Number of input ranges -10 V ... +10 V

    1

  • Number of input ranges -10 mA ... +10 mA

    1

  • Number of input ranges -20 V ... +20 V

    1

  • Number of input ranges -20 mA ... +20 mA

    1

  • Number of input ranges -60 mV ... +60 mV

    0

  • Number of input ranges -100 mV ... +100 mV

    1

  • Number of input ranges -300 mV ... +300 mV

    0

  • Number of input ranges -500 mV ... +500 mV

    0

  • Number of input ranges 0 V ... 1 V

    1

  • Number of input ranges 0 V ... 2 V

    1

  • Number of input ranges 0 V ... 2.5 V

    1

  • Number of input ranges 0 V ... 5 V

    1

  • Number of input ranges 0 V ... 20 V

    1

  • Number of input ranges 0 V ... 24 V

    1

  • Number of input ranges 0 V ... 30 V

    1

  • Number of input ranges 0 mA ... 5 mA

    1

  • Number of input ranges 0 mA ... 10 mA

    1

  • Number of input ranges 0 mA ... 20 mA

    1

  • Number of input ranges 0 mV ... 60 mV

    0

  • Number of input ranges 0 mV ... 100 mV

    0

  • Number of input ranges 0 mV ... 200 mV

    0

  • Number of input ranges 0 mV ... 300 mV

    1

  • Number of input ranges 0 mV ... 500 mV

    1

  • Number of input ranges 1 V ... 5 V

    1

  • Number of input ranges 2 V ... 10 V

    1

  • Number of input ranges 4 mA ... 20 mA

    1

  • Number of input ranges 5 V ... 0 V

    1

  • Number of input ranges 5 V ... 1 V

    1

  • Number of input ranges 10 V ... 0 V

    1

  • Number of input ranges 10 V ... 2 V

    1

  • Number of input ranges 20 mA ... 0 mA

    1

  • Number of input ranges 20 mA ... 4 mA

    1

  • Number of limit values

    2

  • Number of output circuits relays change-over contact

    2

  • Number of output circuits relays normally open contact

    2

  • Number of output circuits transistor potential-free

    0

  • Power consumption

    3 W

  • Primary voltage tolerance

    5 %

  • Rated operation frequency

    0 .. 50 Hz

  • Rated supply voltage at AC

    260 .. 260 V

  • Rated supply voltage at DC

    0 .. 0 V

  • Switching voltage

    250 V

  • Width

    22.5 mm