Converter for Universal Pt100 probes, Harmony Analog, temperature transmitter, 100...100 degree COr

Product ID: 96072541 ! Pre Order
New New
Schneider Electric Converter for Universal Pt100 probes, Harmony Analog, temperature transmitter, 100...100 degree COr RMPT20BD | Elektrika.lv

Price and quantity

* Price is valid while product is in stock. if a chosen item is out of stock at the moment, our specialists will inform you about delivery terms and prices.
(0)
  • e-store price

    114.19 / pcs

  • Quantity

  • Total price VAT included (21%)

    114.19

Availability

* The availability of a product in Elektrika warehouses is indicated below. If the product is in the supplier's warehouse, it may take up to 2-12 business days to arrive at Elektrika warehouse.
  • Riga (Marupe)

    0

  • Daugavpils

    0

  • Valmiera

    0

  • Ventspils

    0

Product details

* The displayed pictures may not match the product
  • Manufacturer

    Schneider Electric

  • Manufacturers ID

    RMPT20BD

  • EAN

    3389110108941

  • Sustainable by Design
    Green Premium™
    Ilgtspējīgs iepakojums Sustainable Packaging
    Product primary packaging free from single-use plastic and uses recycled cardboard.
    Pārredzamība Transparency
    Assessment of the product environmental impacts along its life-cycle and availability of the data through a Product Environmental Profile.
    RoHS/REACh RoHS/REACh
    Compliant with RoHS/REACh regulations

Product parameters

  • Net Weight

    0.108 kg

  • Height

    82 mm

  • Length

    85 mm

  • Sustainability

    +

  • Width

    27 mm

Additional parameters

+
  • Construction type of device

    Other

  • Degree of protection (IP)

    IP20

  • Depth

    80 mm

  • Galvanic separation between input and output

    -

  • Galvanic separation between inputs

    -

  • Galvanic separation between output to output

    -

  • Galvanic separation between supply voltage and all other current circuits

    -

  • Height

    78 mm

  • Inherently safe according to EN 60947-5-6 NAMUR

    +

  • Load

    500 .. 500 Ohm

  • Load influence

    0 %/100%

  • Malfunction message output

    -

  • Mounting method

    Snap mounting support rail

  • Number of channels

    1

  • Number of input ranges +5 V ... -5 V

    0

  • Number of input ranges +10 V ... -10 V

    0

  • Number of input ranges -1 V ... +1 V

    0

  • Number of input ranges -2 V ... +2 V

    0

  • Number of input ranges -2.5 V ... +2.5 V

    0

  • Number of input ranges -5 V ... +5 V

    0

  • Number of input ranges -5 mA ... +5 mA

    0

  • Number of input ranges -10 V ... +10 V

    0

  • Number of input ranges -10 mA ... +10 mA

    0

  • Number of input ranges -20 V ... +20 V

    0

  • Number of input ranges -20 mA ... +20 mA

    0

  • Number of input ranges -60 mV ... +60 mV

    0

  • Number of input ranges -100 mV ... +100 mV

    0

  • Number of input ranges -300 mV ... +300 mV

    0

  • Number of input ranges -500 mV ... +500 mV

    0

  • Number of input ranges 0 V ... 1 V

    0

  • Number of input ranges 0 V ... 2 V

    0

  • Number of input ranges 0 V ... 2.5 V

    0

  • Number of input ranges 0 V ... 5 V

    0

  • Number of input ranges 0 V ... 10 V

    1

  • Number of input ranges 0 V ... 20 V

    0

  • Number of input ranges 0 V ... 24 V

    0

  • Number of input ranges 0 V ... 30 V

    0

  • Number of input ranges 0 mA ... 5 mA

    0

  • Number of input ranges 0 mA ... 10 mA

    0

  • Number of input ranges 0 mA ... 20 mA

    1

  • Number of input ranges 0 mV ... 60 mV

    0

  • Number of input ranges 0 mV ... 100 mV

    0

  • Number of input ranges 0 mV ... 200 mV

    0

  • Number of input ranges 0 mV ... 300 mV

    0

  • Number of input ranges 0 mV ... 500 mV

    0

  • Number of input ranges 1 V ... 5 V

    0

  • Number of input ranges 2 V ... 10 V

    0

  • Number of input ranges 4 mA ... 20 mA

    1

  • Number of input ranges 5 V ... 0 V

    0

  • Number of input ranges 5 V ... 1 V

    0

  • Number of input ranges 10 V ... 0 V

    0

  • Number of input ranges 10 V ... 2 V

    0

  • Number of input ranges 20 mA ... 0 mA

    0

  • Number of input ranges 20 mA ... 4 mA

    0

  • Number of output ranges +5 V ... -5 V

    0

  • Number of output ranges +10 V ... -10 V

    0

  • Number of output ranges -1 V ... +1 V

    0

  • Number of output ranges -2 V ... +2 V

    0

  • Number of output ranges -2.5 V ... +2.5 V

    0

  • Number of output ranges -5 V ... +5 V

    0

  • Number of output ranges -5 mA ... +5 mA

    0

  • Number of output ranges -10 V ... +10 V

    0

  • Number of output ranges -10 mA ... +10 mA

    0

  • Number of output ranges -20 V ... +20 V

    0

  • Number of output ranges -20 mA ... +20 mA

    0

  • Number of output ranges -60 mV ... +60 mV

    0

  • Number of output ranges -100 mV ... +100 mV

    0

  • Number of output ranges -300 mV ... +300 mV

    0

  • Number of output ranges -500 mV ... +500 mV

    0

  • Number of output ranges 0 V ... 1 V

    0

  • Number of output ranges 0 V ... 2 V

    0

  • Number of output ranges 0 V ... 2.5 V

    0

  • Number of output ranges 0 V ... 5 V

    0

  • Number of output ranges 0 V ... 10 V

    0

  • Number of output ranges 0 V ... 20 V

    0

  • Number of output ranges 0 V ... 24 V

    0

  • Number of output ranges 0 V ... 30 V

    0

  • Number of output ranges 0 mA ... 5 mA

    0

  • Number of output ranges 0 mA ... 10 mA

    0

  • Number of output ranges 0 mA ... 20 mA

    0

  • Number of output ranges 0 mV ... 60 mV

    0

  • Number of output ranges 0 mV ... 100 mV

    0

  • Number of output ranges 0 mV ... 200 mV

    0

  • Number of output ranges 0 mV ... 300 mV

    0

  • Number of output ranges 0 mV ... 500 mV

    0

  • Number of output ranges 1 V ... 5 V

    0

  • Number of output ranges 2 V ... 10 V

    0

  • Number of output ranges 4 mA ... 20 mA

    0

  • Number of output ranges 5 V ... 0 V

    0

  • Number of output ranges 5 V ... 1 V

    0

  • Number of output ranges 10 V ... 0 V

    0

  • Number of output ranges 10 V ... 2 V

    0

  • Number of output ranges 20 mA ... 0 mA

    0

  • Number of output ranges 20 mA ... 4 mA

    0

  • Operation temperature

    0 .. 60 °C

  • Rated supply voltage at DC

    24 .. 24 V

  • SIL according to IEC 61508

    None

  • Switching current

    0.2 A

  • Switching frequency

    0 Hz

  • Switching voltage

    10 V

  • Type of electric connection

    Screw connection

  • Type of power supply

    Active

  • Width

    25 mm

Description

What is this product?
This product is a temperature transmitter for Universal Pt100 probes, converting temperature readings into analog signals for monitoring and control. It offers precise temperature measurement with high reliability and protection features, ensuring accurate data for critical applications.

What is the product technical and installation information?
Key benefits include reverse polarity protection, overvoltage protection, short-circuit protection, and high repeat accuracy. The RMPT20BD can be installed on a 35 mm DIN rail or a mounting plate, making it versatile for various setups. The product includes the temperature transmitter unit and is compatible with Pt100 probes, supporting 2, 3, or 4-wire configurations.

What is the product range information?
The Harmony Analog range offers robust performance, easy installation, and compatibility with various industrial standards.