Trip unit MicroLogic 2.3, ComPacT NSX630, 4 poles, electronic basic protections, 630A rating

Toote ID : 9669985 ! Tellimuse järgi
Schneider Electric Trip unit MicroLogic 2.3, ComPacT NSX630, 4 poles, electronic basic protections, 630A rating C6342D630 | Elektrika.lv

Hind ja kogus

* Hinnad kehtivad, kuni kaupa jätkub. Kui antud toode on laost otsas, teavitavad meie spetsialistid teid tarneaegadest ja hindadest.
(0)
  • e-poe hind

    422.48 / pcs

  • Kogus

  • Tasutav summa KM-ga (21%)

    422.48

Kättesaadavus

* Allpool on toodud kauba saadavus Elektrika filiaalides. Kui toode asub tarnija laos, võib tarneaeg Elektrika lattu võtta 2–12 tööpäeva.
  • Riga (Marupe)

    0

  • Daugavpils

    0

  • Valmiera

    0

  • Ventspils

    0

Teave toote kohta

* Piltidel vaid informatiivne tähendus
  • Tootja

    Schneider Electric

  • Tootja ID

    C6342D630

  • EAN

    3606482003279

  • Sustainable by Design
    Green Premium™
    Ilgtspējīgs iepakojums Sustainable Packaging
    Product primary packaging free from single-use plastic and uses recycled cardboard.
    Pārredzamība Transparency
    Assessment of the product environmental impacts along its life-cycle and availability of the data through a Product Environmental Profile.
    RoHS/REACh RoHS/REACh
    Compliant with RoHS/REACh regulations

Toote parameetrid

  • Netokaal

    1.774 kg

  • Kõrgus

    177 mm

  • Laius

    136 mm

  • Pikkus

    216 mm

  • Sustainability

    +

Täiendavad parameetrid

+
  • Current setting delayed short-circuit release

    375 .. 6300 A

  • Current setting undelayed short-circuit release

    6900 .. 6900 A

  • Depth

    112.6 mm

  • End value adjustment range undelayed short-circuit release

    6900 A

  • External power supply required

    -

  • Initial value of the undelayed short-circuit release - setting range

    6900 A

  • Kõrgus

    94.6 mm

  • Laius

    184.7 mm

  • Number of auxiliary contacts as change-over contact

    0

  • Number of auxiliary contacts as normally closed contact

    0

  • Number of auxiliary contacts as normally open contact

    0

  • Number of poles

    4

  • Operating voltage at AC 50 Hz

    690 .. 690 V

  • Operating voltage at AC 60 Hz

    690 .. 690 V

  • Overload release current setting

    250 .. 630 A

  • Rated control supply voltage Us at AC 50HZ

    690 .. 690 V

  • Rated control supply voltage Us at AC 60HZ

    690 .. 690 V

  • Rated permanent current Iu

    630 A

  • Rated switch current

    630 A

  • Short-circuit release function

    Delayed

  • Type of motor protection

    Electronic release

  • Voltage type (operating voltage)

    AC

  • Voltage type for actuating

    AC

  • With ground fault protection function

    -