iDPN N Vigi Residual Current Breaker with Overload protection 1P + N 32A 30mA class A

Product ID: 3270029 ! Pre Order
Schneider Electric iDPN N Vigi Residual Current Breaker with Overload protection 1P + N 32A 30mA class A A9D32632 | Elektrika.lv

Price and quantity

* Price is valid while product is in stock. if a chosen item is out of stock at the moment, our specialists will inform you about delivery terms and prices.
(0)
  • e-store price

    58.33 / pcs.

  • Quantity

  • Total price VAT included (21%)

    58.33

Availability

* The availability of a product in Elektrika warehouses is indicated below. If the product is in the supplier's warehouse, it may take up to 2-12 business days to arrive at Elektrika warehouse.
  • Riga (Marupe)

    0

  • Daugavpils

    0

  • Valmiera

    0

  • Ventspils

    0

Product details

* The displayed pictures may not match the product

Product parameters

  • Net Weight

    0.225 kg

  • Classification

    С

  • Height

    80 mm

  • Length

    40 mm

  • Number of poles

    1+N

  • Product series

    Acti 9

  • Rated Residual Current

    30 mA

  • Rated current

    32 A

  • Width

    100 mm

Additional parameters

+
  • Ambient temperature during operating

    25 .. 60 °C

  • Anti-nuisance tripping version

    -

  • Built-in depth

    44 mm

  • Concurrently switching N-neutral

    +

  • Connectable conductor cross section multi-wired

    1 .. 10 mm²

  • Connectable conductor cross section solid-core

    1 .. 16 mm²

  • Current limiting class

    3

  • Degree of protection (IP)

    IP20

  • Disconnection characteristic

    Other

  • Flush-mounted installation

    -

  • Frequency

    50 Hz

  • Leakage current type

    A

  • Number of poles (total)

    2

  • Number of protected poles

    1

  • Over voltage category

    3

  • Pollution degree

    3

  • Rated current

    32 A

  • Rated fault current

    0.03 mA

  • Rated impulse withstand voltage Uimp

    4 kV

  • Rated insulation voltage Ui

    400 V

  • Rated short-circuit breaking capacity IEC 60947-2

    - kA

  • Rated short-circuit breaking capacity Icn acc. EN 61009-1

    6 kA

  • Rated short-circuit breaking capacity acc. EN 61009

    6 kA

  • Rated voltage

    230 V

  • Release characteristic

    C

  • Suitable for flush-mounted installation

    -

  • Surge current capacity

    0.25 kA

  • Voltage type

    AC

  • Width in number of modular spacings

    2

  • With interlocking device

    -