DPN Vigi K 1F+N B16 AC 30mA Residual Current Breaker with Overload protection Acti9 Lite

Toote ID : 3270026 Laos
Schneider Electric DPN Vigi K 1F+N B16 AC 30mA Residual Current Breaker with Overload protection Acti9 Lite A9D22616 | Elektrika.lv

Hind ja kogus

* Hinnad kehtivad, kuni kaupa jätkub. Kui antud toode on laost otsas, teavitavad meie spetsialistid teid tarneaegadest ja hindadest.
(0)
  • e-poe hind

    29.79 / pcs.

  • Kogus

  • Tasutav summa KM-ga (21%)

    29.79

Kättesaadavus

* Allpool on toodud kauba saadavus Elektrika filiaalides. Kui toode asub tarnija laos, võib tarneaeg Elektrika lattu võtta 2–12 tööpäeva.
  • Riga (Marupe)

    5

  • Daugavpils

    0

  • Valmiera

    7

  • Ventspils

    0

  • Tarnija ladu

    157

Teave toote kohta

* Piltidel vaid informatiivne tähendus
  • Tootja

    Schneider Electric

  • Tootja ID

    A9D22616

  • EAN

    3606480569388

  • Sustainable by Design
    Green Premium™
    Ilgtspējīgs iepakojums Sustainable Packaging
    Product primary packaging free from single-use plastic and uses recycled cardboard.
    Pārredzamība Transparency
    Assessment of the product environmental impacts along its life-cycle and availability of the data through a Product Environmental Profile.
    RoHS/REACh RoHS/REACh
    Compliant with RoHS/REACh regulations

Toote parameetrid

  • Netokaal

    0.218 kg

  • Klass

    B

  • Kõrgus

    84 mm

  • Laius

    100 mm

  • Nimivool

    16 A

  • Pikkus

    40 mm

  • Pooluste arv

    1+N

  • Rated Residual Current

    30 mA

  • Seeria

    Acti 9 Lite

  • Sustainability

    +

Täiendavad parameetrid

+
  • Ambient temperature during operating

    -5 .. 40 °C

  • Anti-nuisance tripping version

    -

  • Built-in depth

    44 mm

  • Concurrently switching N-neutral

    -

  • Connectable conductor cross section multi-wired

    1 .. 16 mm²

  • Connectable conductor cross section solid-core

    1 .. 25 mm²

  • Current limiting class

    3

  • Degree of protection (IP)

    IP20

  • Disconnection characteristic

    Undelayed

  • Flush-mounted installation

    -

  • Frequency

    50 Hz

  • Leakage current type

    AC

  • Number of poles (total)

    2

  • Number of protected poles

    1

  • Over voltage category

    3

  • Pollution degree

    3

  • Rated current

    16 A

  • Rated fault current

    0.03 A

  • Rated fault current

    0.03 mA

  • Rated impulse withstand voltage Uimp

    4 kV

  • Rated insulation voltage Ui

    400 V

  • Rated short-circuit breaking capacity IEC 60947-2

    - kA

  • Rated short-circuit breaking capacity Icn acc. EN 61009-1

    6 kA

  • Rated short-circuit breaking capacity acc. EN 61009

    6 kA

  • Rated voltage

    240 V

  • Release characteristic

    B

  • Suitable for flush-mounted installation

    -

  • Surge current capacity

    0.25 kA

  • Voltage type

    AC

  • Width in number of modular spacings

    2

  • With interlocking device

    +

Tagasiside (0)